INSTALLATION MANUAL V3.0
Warning: This manual contains information on limitations regarding product use and func-
tion and information on the limitations as to liability of the manufacturer.

Questions and Answers

  • R
    rbakerSep 23, 2025
    Why are only the green LEDs flashing on my DSC Cell Phone?
    • J
      John WilliamsSep 23, 2025
      If only the green LEDs are flashing on your DSC Cell Phone, the hardware default jumper is installed and must be removed.
  • L
    Linda BrownAug 23, 2025
    What to do if the yellow LED flashes 6 times on my DSC TL260?
    • L
      Lisa RoblesAug 25, 2025
      If the yellow LED on your DSC Security System flashes 6 times, this indicates an Ethernet trouble. To resolve this, first check with your ISP to confirm that network service is active in your area. Ensure your Ethernet cable is securely inserted into both the RJ45 jack of the Communicator and the NID. Verify that the yellow LINK light on both the Communicator and the NID are ON. If the link light is OFF on the NID, try restarting it. If the problem continues, replace the Ethernet cable. If DHCP is used, ensure that the unit has been assigned an IP address from the server. Check in Panel Sections [851] and [992] to verify a valid IP address is programmed. If not, contact your network administrator.
  • K
    Kayla DouglasAug 25, 2025
    How to fix all LEDs being off on my DSC TL260 Security System?
    • K
      Krystal CuevasAug 26, 2025
      If all the LEDs on your DSC Security System are off, it typically indicates a power issue. Check your power connections to both the Control Panel and the Communicator module. Also, make sure the PC-LINK cable is properly attached. If you have a TL265 and it's in Power Save Mode, note that only the yellow trouble LED will function; check the AC source to the Control Panel. Alternatively, the Control Panel may be in keypad blanking; press any key on the keypad to remove blanking momentarily.
  • T
    Theodore FloresAug 27, 2025
    What does it mean when the yellow LED flashes 8 times on my DSC Security System?
    • T
      Tammy TorresAug 27, 2025
      If the yellow LED on your DSC Security System flashes 8 times, it indicates a receiver supervision trouble. This occurs when supervision is enabled, but the unit cannot successfully communicate with the receiver. Contact your central station for assistance.
  • J
    Joshua VelasquezAug 27, 2025
    Why is the yellow LED flashing 12 times on my DSC TL260?
    • X
      xsimsAug 27, 2025
      If the yellow LED on your DSC Security System flashes 12 times, it means there's a module configuration trouble. This usually happens when the System Account Code or Receiver Account Code is programmed with all 0s or all Fs (e.g., FFFFFF). To fix this, check Sections [851][021], [101], and [111] to confirm the account numbers.
  • K
    Kyle MedinaSep 16, 2025
    What does it mean when the yellow LED on my DSC Cell Phone flashes 4 times?
    • M
      meagan52Sep 16, 2025
      If the yellow LED on your DSC Cell Phone flashes 4 times, the SIM card has an incorrect PIN programmed or has a PIN that the module does not recognize. Replace the SIM card.
  • W
    walshamySep 13, 2025
    What does it mean when the yellow LED on my DSC Cell Phone flashes 9 times?
    • L
      lynndoyleSep 13, 2025
      If the yellow LED on your DSC Cell Phone flashes 9 times, the unit has exhausted all communications attempts to all programmed receiver for events generated by the Communicator. Restart the system, if trouble persists, contact your dealer.
  • A
    Ann KempSep 14, 2025
    Why is the trouble LED on my DSC Cell Phone flashing twice?
    • J
      Johnny AllenSep 15, 2025
      If the trouble LED on your DSC Cell Phone is flashing twice, it indicates a panel supervision trouble. Check that Section [382] Toggle Option [5] is ON (cellular/Ethernet Module Enabled). Also, ensure the PC-LINK cable between the panel and communicator is connected properly (not reversed) and is securely in place.
  • J
    jasonparkSep 5, 2025
    Why is the yellow LED on my DSC Cell Phone solid?
    • L
      lucasmcculloughSep 6, 2025
      A solid yellow LED on your DSC Cell Phone indicates insufficient signal strength. First, confirm that cellular network service is active in your area. Next, ensure the antenna is securely connected to the radio and that the antenna stub cable is also securely connected. If you're using an external antenna, check that it's securely screwed onto the antenna cable connector and inspect it for any damage or shorts.
  • J
    John MorenoSep 3, 2025
    Why are the green LEDs flashing rapidly on my DSC TL260?
    • A
      Alexandra ShepardSep 3, 2025
      If the green LEDs are flashing rapidly on your DSC Security System, it means the hardware default jumper is still in place. Remove the jumper.

Summary

General

Important Installation Notes

Key instructions and warnings that must be followed during installation.

Safety Information for Users

Instructions for the installer to convey to the system user regarding product safety.

Pre Installation Configuration

Remote Programming Configuration via DLS 5

Step-by-step guide for configuring the communicator remotely using DLS 5 software.

Communicator Installation Configuration

Installing the Ethernet Cable

Instructions for correctly installing the Ethernet cable for the TL2603G/TL260 models.

SIM Card Installation and Removal

Procedure for inserting and removing the SIM card from the communicator.

Installing Cellular;Ethernet Communicator in Panel

Installing Communicator with PC Panels

Detailed steps for installing the communicator into specific panel models.

Installing Cellular;Ethernet Communicator in Panel (continued)

Module Power Connection to Panel

Wiring instructions for connecting the communicator's power to the panel's terminals.

Installing Cellular;Ethernet Communicator in Panel (continued)

Keybus Connection Procedure

Steps to connect the communicator to the panel via the keybus.

Install Network Cable

Instructions for routing and plugging in the network cable for supported models.

Communicator Placement Test

Initial Panel Programming

Communicator Status LEDs

Yellow Trouble LED Indicator

Explains the yellow LED's function and coded flashes for troubleshooting.

Panel Supervision Trouble Indicator

Details the conditions and reporting codes for Panel Supervision Trouble.

Communicator Status LEDs (continued)

Communicator Reset and Update Procedures

Factory Defaults Reset Procedure

Steps to reset the communicator to its factory default settings.

Firmware Update Process

Information on how to update the device's firmware.

Communicator Troubleshooting Guide

Trouble LED Indications and Solutions

Lists trouble indications, possible causes, and solutions based on LED flashes.

Ethernet;Cellular Programming Options

Ethernet IP Address Configuration

Settings for configuring the communicator's Ethernet IP address.

Ethernet;Cellular Programming Options (continued)

Communicator Status Code Interpretation

Explains the 6-digit hexadecimal code indicating communicator status.

Radio Signal Strength Indicators and Actions

Details signal strength indicators, CSQ levels, and required actions.

Ethernet;Cellular Programming Options (continued)

Installer Code Configuration

Setting the installer code for accessing communicator programming.

System Test Transmission Options

Settings for configuring periodic test transmissions to receivers.

Firmware Update Diagnostics

Provides diagnostic codes related to firmware update status.

Trouble Code Indications and Causes

Lists trouble indicators, their types, and causes.

Ethernet;Cellular Programming Options (continued)

Ethernet;Cellular Programming Worksheets

Ethernet;Cellular Programming Worksheets (continued)

Ethernet;Cellular Programming Worksheets (continued)

Software Default Reset Procedure

Procedure to reset the communicator to factory default settings.

EN50131-1 Installation Requirements

EN50131 Compliant Installation Details

Details specific programming options and certifications for EN50131 compliance.