Appendix 2: Reporting Codes
Section # Definition
Dialer Dir-
ection*
Automatic Contact ID
Codes
SIA Auto Rep Codes**
Recent Closing - Alarm occurs within two minutes of system
arming
A/R E(4)59-UUU CR-UUUU
Burglary Verified A/R E(1)39-000 BV-0000
Burglary Not Verified A/R E(3)78-000 BG-0000
Alarm Canceled before expiry of alarm cancellation timer A/R E(4)A6-UUU OC-UUUU
Priority Alarm and Restoral Events
[F] Key alarm/restore A/R
E(1)1A-000
R(1)1A-000
FA-0000 / FH-0000
[A] Key alarm/restore A/R
E(1)AA-000
R(1)AA-000
MA-0000 / MH-0000
[P] Key alarm/restore A/R
E(1)2A-000
R(1)2A-000
PA-0000 / PH-0000
Fire alarm by wireless/ alarm restore A/R E(1)1A-0000/ R(1)1A-0000 FA-0000/FH-0000
Auxiliary alarm by wireless/ alarm restore A/R E(1)AA-0000/ R(1)AA-0000 MA-0000/MH-0000
Panic alarm by wireless/ alarm restore A/R E(1)2A-0000/ R(1)2A-0000 PA-0000/PH-0000
Fire alarm by interactive/ alarm restore A/R E(1)11A-0000/ R(1)11A-0000 FA-0000/FH-0000
Auxiliary alarm by interactive/ alarm restore A/R E(1)AA-0000/ R(1)AA-0000 MA-0000/MH-0000
Panic alarm by interactive/ alarm restore A/R E(1)2A-0000/ R(1)2A-0000 PA-0000/PH-0000
Miscellaneous Closing
] Zone Bypass at time of arming O/C E(5)7A-ZZZ UB-ZZZZ
Zone unbypass O/C R(5)7A-ZZZ UU-ZZZZ
Testing
Walk Test Begin/End T
E(6)A7-UUU
R(6)A7-UUU
TS-UUUU/TE-UUUU
Periodic Test T E(6)A2-000 RP-0000 / RY-0000
Periodic Test with Trouble T E(6)A8-000 RY-0000
System Test T E(6)A1-000 RX-0000
Maintenance
General System trouble. An RF jam trouble occurred MA/R E(3) AA-000 YX-0000
Fire trouble/restore MA/R
E(3)73-000
R(3)73-000
FT-0000 / FJ-0000
Heat trouble/restore MA/R
E(3)8A-ZZZ
R(3)8A-ZZZ
KT-ZZZZ / KJ-ZZZZ
Cold Start - System has restarted after total power loss MA/R R(3) A5-000 RR-0000
Smoke detector low sensitivity trouble/restore MA/R E(3)93-ZZZ FT-0000/ FJ-0000
Event Buffer 75% Full MA/R E(6)22-000 JL-0000
Installer Lead In - Installer Programming has been entered MA/R E(6)27-000 LB-0000
Installer Lead out - Installer Programming has been exited MA/R E(6)28-000 LS-0000
Panel firmware update begin/ successful MA/R
E(9)01-900
R(9)01-900
LB-0900 / LS-0900
Panel firmware update fail MA/R E(9)02-900 LU-0900