Appendix 2: Reporting Codes
Section # Definition
Dialer Dir-
ection*
Automatic Contact ID
Codes
SIA Auto Rep Codes**
Periodic test with trouble MA/R E(6)A2-RRRR RP-RRRR
*
A/R = alarms/restores; T/R = tampers/restorers; O/C = openings/closings; MA/R = maintenance alarms/restores; T = test trans-
missions
** UUU = user number. Note that for CID, enter 999 for user 1000. ZZZ/ZZZZ = zone number.
*** Zones and panic pendants are identified, wireless keys can be identified for openings and closings.
Contact ID & SIA Zone Alarm/Restore Event Codes
(as per SIA DCS: ‘Contact ID 01-1999):
The table below defines the meaning of all Contact ID and SIA zone alarm/restore event codes.
Zone Definition SIA Auto Rep Codes Contact ID Auto Rep Codes
Delay 1 BA-ZZZZ / BH-ZZZZ E(1) 3A - ZZZ / R(1)3A- ZZZ
Delay 2 BA-ZZZZ / BH-ZZZZ E(1) 3A - ZZZ / R(1)3A- ZZZ
Instant BA-ZZZZ / BH-ZZZZ E(1) 3A - ZZZ / R(1)3A- ZZZ
Interior BA-ZZZZ / BH-ZZZZ E(1) 3A - ZZZ / R(1)3A- ZZZ
Interior Stay/Away BA-ZZZZ / BH-ZZZZ E(1) 3A - ZZZ / R(1)3A- ZZZ
Delay Stay/Away BA-ZZZZ / BH-ZZZZ E(1) 3A - ZZZ / R(1)3A- ZZZ
Day Zone BA-ZZZZ / BH-ZZZZ E(1) 3A - ZZZ / R(1)3A- ZZZ
24-Hr. Burglary BA-ZZZZ / BH-ZZZZ E(1) 3A - ZZZ / R(1)3A- ZZZ
Standard 24-Hr. Fire (Wireless) FA-ZZZZ / FH-ZZZZ E(1) 1A - ZZZ / R(1)1A - ZZZ
24-Hr.Low Temperature ZA-ZZZZ / ZH-ZZZZ E(1) 59 - ZZZ / R(1)59-ZZZ
24-Hr High Temperature KA-ZZZZ / KH-ZZZZ E(1) 58 - ZZZ / R(1)58 - ZZZ
24-Hr. Non Alarm (Walk Test Only) BA-ZZZZ / BH-ZZZZ E(1) 3A - ZZZ / R(1)3A- ZZZ
24-Hr. Supervisory Buzzer UA-ZZZZ / UH-ZZZZ E(1) 5A - ZZZ / R(1)5A - ZZZ
24-Hr. Auto Verified Fire (Wireless) FA-ZZZZ / FH-ZZZZ E(1) 1A - ZZZ / R(1)1A - ZZZ
24-Hr. CO Alarm GA-ZZZZ / GH-ZZZZ E(1) 62 - ZZZ / R(1)62 - ZZZ
24-Hr. Holdup HA-ZZZZ / HH-ZZZZ E(1) 22 - ZZZ / R(1)22 - ZZZ
24-Hr. Panic PA-ZZZZ / PH-ZZZZ E(1) 2A - ZZZ / R(1)2A - ZZZ
24-Hr. Flood WA-ZZZZ / WH-ZZZZ E(1) 54 - ZZZ / R(1)54 - ZZZ
24-Hr. Auxiliary MA-ZZZZ / MH-ZZZZ E(1) AA - ZZZ / R(1)AA - ZZZ
Push to Set (Walk Test Only) BA-ZZZZ / BH-ZZZZ E(1) 3A - ZZZ / R(1)3A - ZZZ
ZZZ/ZZZZ = zones 001-128