Protection
XLR 5 or 3 pole connector
If the display showing the DMX address flashes, then one of the following errors has
occurred:
The use of a thermal magnetic circuit breaker is recommended for each Xr7 Wash.
A good earth connection is essential for the correct operation of the projector.
The unit operates using a digital DMX 512 (1990) signal. Connection between the
control box and the projector or between projectors must be carried out using a two pair
screened ø0.5 mm cable and a CANNON .
Ensure that all conductors are isolated from one another and from the metal plug
housing.
The plug housing must be isolated. Connect the control box signal to the DMX IN
projector plug and connect it to the next projector by connecting the DMX OUT plug on
the first projector to the DMX IN plug on the second.
In this way, all the projectors are cascade connected.
NB.
- DMX signal not present
- DMX address not valid
- DMX reception problem
The standard configuration of the Xr7 Wash is with XLR 5 pole connection.
To convert to an XLR 3 pole configuration proceed as follows:
1) Unscrew the external cover (photo 1).
2) Unscrew the screws that fix the connectors to the panel (photo 2).
3) Rotate the electronic card by 180° (photo 3).
4) Position the 3 pole connectors in the special holes and close.
7- DMX SIGNAL CONNECTION
5
3
42
1
1=GND
2=DATA-
3=DATA+
CONTROLLER
STANDARD
DMX 512
Photo 2Photo 1 Photo 3