32
DY CAT 48
The following actions must be taken before the system is started:
1 Complete calibration
2 Start the MDI display(s)
3 Fault code checks
Carry out the following before start:
1 Open the fuel tap
2 Open the seawater valve
3 Turn the main switches on
IMPORTANT!
Never switch off the current at the main switch when the engine
is running. It may damage the alternator.
4 Start the engine compartment fan, where fitted, and allow it to
run for at least four minutes.
5 Check that there is sufficient fuel for the planned trip.
6 Check that the fuel system is vented.
Start the engine
Turn the ignition on.
Switch on the ignition by pressing the control panel On/ Off button.
Control instruments and alarms
If a fault is registered it will be indicated on the tachometer display by a flashing light.
Start using the start button
Depress the start button. Release the start button as soon as the engine starts. Abort the start
attempt if the engine does not start within 20 - 30 seconds.
Overheating protection
If the starter motor is allowed to run for its maximum activation time, the
circuit will be disconnected to protect the starter motor from
overheating. Allow the starter motor to cool for at least five minutes (if
possible) before making a new start attempt.