CARE AND CLEANING
WEEKLY CLEANING INSTRUCTIONS
1. Clean Proofer. Turn the proofer off and
allow elements to cool. Remove the bottom
panel (remove screw). Remove excess
water by wiping it up with a dry cloth.
Clean bottom panel to remove any mineral
deposits and debris with hot soapy water
and follow with clean damp cloth.
2. Clean Opti-Mist proofer spray Nozzle.
A. Remove nozzle assembly by depressing
latch on quick-connect tting and pull
nozzle out toward fan blade.
B. Soak nozzle in plain white vinegar for 4-8
hours to dissolve mineral deposits. Wipe
residue from nozzle and rinse in clean
water.
C. Do not insert objects into nozzle outlet
as this can change the water spray
performance.
D. Replace nozzle assembly if mineral
deposits from hard water cannot be
removed.
E. Reinstall nozzle by inserting into quick-
connect tting until fully seated.
Figure: Opti-Mist
TM
Quick Connect Nozzle
TM
TM
PROOFER OVEN INTERIOR AND
RACKS ARE VERY HOT AND COOL
SLOWLY.
ALLOW TO COOL BEFORE
HANDLING.
ELECTRICAL SHOCK HAZARD.
DO NOT WASH WITH WATER JET
OR HOSE.
RISK OF CUT FROM ROTATING FAN
BLADE.
DISCONNECT POWER TO SERVICE.
RISK OF BURN FROM HEATING
ELEMENTS.
DISCONNECT POWER AND ALLOW
TO COOL TO SERVICE.
DO NOT USE OVEN CLEANERS,
CAUSTIC CLEANERS, DEGREASERS,
ACIDS, AMMONIA PRODUCTS,
ABRASIVE CLEANERS, STEEL WOOL,
OR ABRASIVE PADS CONTAINING
IRON. THESE CAN DAMAGE THE
STAINLESS STEEL, DOOR GASKETS
AND PLASTIC SURFACES.