Table 5-1 Troubleshooting reference
Troubleshooting Reference
Problem
Possible Cause Solution
AC appliance Battery has discharged Tum the AC outlet ON/OFF switch
will not to 10.5
V.
off
and recharge the Duracell®
operate; Powerpack.
audible alarm
is sounding. Inverter has
Tum the AC outlet
ON/OFF switch
overheated due to poor
off
and allow the Duracell®
ventilation or
Powerpack to cool for
15
minutes or
excessively warm more. Clear blocked fan opening or
environmental remove objects covering the unit,
conditions. then restart the Duracell®
Powerpack.
Move to a cooler environment.
----------------_.--------------
Over- Inverter has Tum
off
the AC outlet ON/OFF
temperature overheated due to poor switch, and let the Duracell®
shutdown
ventilation or Powerpack cool down.
excessively warm
environmental
conditions.
Alarm sounds Internal battery is
Tum the AC outlet
ON/OFF switch
nearly discharged.
OFF and recharge the Duracell®
(11.0 V).
Powerpack.
If
you ignore this
warning, the
Duracell® Powerpack
automaticallyswitches
off
when the battery
reaches 10.5
V.
Run time is
Internal battery is not
Recharge using the AC charger, until
less than
fully charged.
green
Charging
Status
light is
expected.
steady.
AC appliance power
Check AC appliance power or
consumption is higher
wattage rating (or current draw for
than expected.
12
V DC appliances) and compare
with Table
3-1
on page
15
and Table
3-2 on page 18.
975-0339-01-01