EasyManuals Logo

DURAG D-R 290 User Manual

DURAG D-R 290
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Contents
4
D-R 290
4.3 System components........................................................................................................................
50
4.3.1 Possible system configurations.......................................................................................................
51
4.4 Applications, Designated use.......................................................................................................... 53
4.5 Conformity/approval........................................................................................................................
54
4.6 Designation of device components for the D-R 290........................................................................
54
4.7 Identification of the product............................................................................................................. 57
4.7.1 Information about the type label......................................................................................................
59
5 Installation 63
5.1 Safety
.............................................................................................................................................. 63
5.1.1 Transport to the place of installation................................................................................................
64
5.1.2 Skill levels of personnel for installation and commissioning............................................................
64
5.2 Preparation for installation...............................................................................................................
64
5.2.1 Preconditions for operation..............................................................................................................
66
5.2.2 Instructions for planning the electrical connections to the system...................................................
66
5.2.3 Instructions for selection the device variant and measuring point...................................................
67
5.2.4 Free space around the device housing...........................................................................................
69
5.3 System installation sequence :........................................................................................................ 69
5.4 Installation of the D−R 290 measuring head and reflector .............................................................
70
5.4.1 Standard installation of the welded-in pipes with adjustment flanges.............................................
70
5.4.2 Installation variants..........................................................................................................................
73
5.4.3 Alignment of the tube stubs.............................................................................................................
76
5.4.4 Installation of the measuring head and reflector..............................................................................
76
5.4.5 Electrical connections to the measuring head.................................................................................
79
5.4.6 Meaning of the LEDs....................................................................................................................... 80
5.4.7 Configuration of the relay outputs....................................................................................................
81
5.5 Installation of the D-SK 290 protective device ................................................................................
83
5.5.1 Installation sequence for the measuring head and reflector (when the D-SK 290 protective device is
used)
................................................................................................................................................ 84
5.5.2 Display LEDs of the control electronics...........................................................................................
87
5.5.3 Installation protective device D-SK 290...........................................................................................
87
5.5.4 D-SK AE electrical connection......................................................................................................... 88
5.5.5 Configuring the protective device....................................................................................................
92
5.5.6 Checking the protective device........................................................................................................
92
5.5.7 Commissioning the D-SK AE...........................................................................................................
93
5.6 Installation of the D-ISC 100 control unit.........................................................................................
96
5.6.1 Connecting the supply and control unit...........................................................................................
96
5.7 Installation of the supply unit...........................................................................................................
97
5.7.1 Installation of the D-TB 100 supply unit...........................................................................................
97
5.7.2 Electrical connection to the D-TB 100 supply unit........................................................................... 98
5.8 Installation of the purge air unit.....................................................................................................
101
5.8.1 Selection of an installation location of the purge air unit (blower).................................................
101
5.8.2 Arrangement and installation of the purge air unit.........................................................................
101
5.8.3 Electrical installation of the purge air unit......................................................................................
102
5.8.4 Electrical connection for the purge air motor.................................................................................
102
5.9 Active operation.............................................................................................................................
103
5.10 Dismantling and disposal............................................................................................................... 103
5.10.1 Dismantling....................................................................................................................................
103
5.10.2 Disposal of the Dust Concentration and Opacity Monitor..............................................................
104
5.10.3 RoHS compliance.......................................................................................................................... 104
6 Commissioning 107
6.1 Optical alignment...........................................................................................................................
107

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DURAG D-R 290 and is the answer not in the manual?

DURAG D-R 290 Specifications

General IconGeneral
BrandDURAG
ModelD-R 290
CategoryMonitor
LanguageEnglish

Related product manuals