EasyManua.ls Logo

Dvorak Spider ILD01 - 8 SAFETY SYSTEMS; 8.1 MOWER SAFETY SYSTEMS

Dvorak Spider ILD01
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation manual - Spider ILD01
24 / 52 rev. 10-01-05-2011
8 SAFETY SYSTEMS
8.1 MOWER SAFETY SYSTEMS
The product is controlled by a remote radio controller. This means that the operator is not close to the mower at
all times and cannot use controls on the mower. For the safety of the operator and other persons the following
table lists various situations and actions:
The mower is out of the signal range.
The EMERGENCY STOP command is
automatically generated.
Radio signal failure.
The EMERGENCY STOP command is
automatically generated
Another machine with the same frequency
is working in the vicinity.
The EMERGENCY STOP command is
automatically generated.
Emergency situations - shutting off by the
emergency stop button.
Push the EMERGENCY STOP button on
the radio controller.
Push the EMERGENCY STOP button
on the body of the mower.
Safety Interlocks prevent the engine
from starting.
If the mowing blade clutch is engaged.
If the transmission is not set to a neutral
position.
If the radio connection is not
established properly.
The EMERGENCY STOP command (automatic or manual) has the following effects:
1. Engine stops
2. Steering of wheels is blocked
3. Travelling is blocked
4. Starter is blocked
5. Mowing blade clutch disengages
6. Ignition is turned off

Table of Contents

Other manuals for Dvorak Spider ILD01