1
MODEL #DGW1904BDP-D
VERTICAL GAS SMOKER
Français p.
XX
Español p.
XX
Français p. 29
Español p. 57
ATTACH YOUR RECEIPT HERE
Purchase Date
Questions, problems, missing parts?
Before returning to your retailer, call our customer
service department at 1-877-447-4768, 8:30 a.m. 4:30 p.m. CST, Monday Friday or log
on to customerservice@ghpgroupinc.com.
ANS Z21.89-2013
CSA 1.18-2013
REV. 1/21/15
70-10-114
Outdoor Cooking
Specialty Gas
Appliances

Other manuals for Dyna-Glo DGW1904BDP-D-1

Questions and Answers

  • T
    Terry BradleyAug 10, 2025
    What to do if Dyna-Glo Smoker has flare-up?
    • T
      Tracy AndersonAug 10, 2025
      If your Dyna-Glo Smoker experiences a flare-up, it could be due to several reasons. First, you might be cooking at excessive temperatures, so try reducing the flame level. Grease and residue build-up can also cause flare-ups, so ensure you clean the components regularly. If you're cooking meat with excessive fat, trim the fat before cooking. Finally, marinades with excessive oil can lead to flare-ups, so consider using a non-oil based marinade.
  • W
    William JonesAug 15, 2025
    What to do if my Dyna-Glo Smoke Alarm is flaring up?
    • M
      Michael MurphyAug 16, 2025
      Flare-ups on your Dyna-Glo Smoke Alarm can occur due to several reasons. You might be cooking at excessive temperatures, so try reducing the flame level. Grease and residue build-up can also cause flare-ups, so be sure to clean the components regularly. If you're cooking meat, trim excess fat before cooking. Finally, avoid oil-based marinades, as excessive oil can contribute to flare-ups; use a non-oil based marinade instead.
  • J
    Jessica GibsonAug 20, 2025
    Why won't my Dyna-Glo Smoke Alarm burner light with the igniter?
    • C
      Cynthia Neal MDAug 20, 2025
      If the burner on your Dyna-Glo Smoke Alarm won't light using the igniter, several issues could be the cause. The igniter electrode might be covered with grease or residue; if so, clean the igniter electrode. Also, the igniter electrode may have a loose or disconnected wire, so check the connection and reconnect any loose wires. If no spark is being generated, replace the AAA battery inside the igniter. Ensure that the LP cylinder isn't empty and that the cylinder valve is open. Finally, a vapor lock may have occurred at the coupling nut to the LP cylinder; in this case, turn off the knob and LP cylinder valve, disconnect the coupling nut, reconnect it, and try again.
  • K
    Karen WalkerAug 26, 2025
    How to fix a yellow sooty flame on my Dyna-Glo Smoke Alarm?
    • D
      Daniel HansenAug 26, 2025
      A yellow, sooty flame on your Dyna-Glo Smoke Alarm can be caused by a few things. It could be due to excessive cooking temperature, so reduce the flame level. Another cause might be an obstruction of gas flow; check and clean the venturi tube and burner. Also, check if the ventilation or damper is closed; if so, adjust them accordingly.
  • D
    davidallenAug 31, 2025
    What to do if the flame keeps going out on my Dyna-Glo Smoke Alarm?
    • N
      Natasha PinedaAug 31, 2025
      If the flame on your Dyna-Glo Smoke Alarm keeps going out, it could be due to a disconnected gas supply hose; make sure to reconnect it. High or gusting winds can also cause the flame to extinguish, so move the grill out of the windy area.
  • A
    Alexandra HurstSep 4, 2025
    Why Dyna-Glo Smoke Alarm burner will not light with a match?
    • T
      Tiffany EspinozaSep 4, 2025
      If the burner on your Dyna-Glo Smoke Alarm won't light with a match, it's likely due to no gas flow or an obstructed gas flow. Check the fuel level and clean the venturi tube and burner.