Amplifier model L2800FD/C2800FDi
Signal Processing FIR Filters, Audio Limiters
Output delay per channel,
31 band GEQ per channel,
PEQ per channel,
Load impedance
Accessories RMK15 (rear rack mount kit), Multi Amplifier Remote Control
(MARC) software
Test signal for max. output power according IHF-A-202 (Dynamic-Headroom, burst 1 kHz/20
ms on/480 ms off/low level -20 dBu).
Amplifier model L3600FD/C3600FDi
Load Impedance 2 Ω 2.7 Ω 4 Ω 8 Ω
Maximum Output Power, Single Channel 3200 W 2700 W 1800 W 950 W
Maximum Output Power, Dual Channel 3000 W 2500 W 1700 W 900 W
Maximum Output Power, Bridged - - 6000 W 3400 W
Maximum RMS Voltage Swing
THD = 1%, 1 kHz
90.6 V
Voltage Gain
Ref.1 kHz
32.0 dB
THD at 1200 W/4
Ω
MBW = 80 kHz, 1 kHz
< 0.05%
IMD-SMPTE,
60 Hz, 7 kHz
< 0.1%
DIM30
,
3.15 kHz, 15 kHz
< 0.05%
Maximum Input Level +21 dBu
Crosstalk
ref. 1 kHz, at 100 W/4
Ω
< -80 dB
Frequency Response
,
ref. 1 kHz
10 Hz to 21 kHz (±1 dB)
Input Impedance,
Active Balanced
20 k Ω
Signal to Noise Ratio Amplifier,
A-weighted, ref to Max. Output Power @ 8
Ω
>109 dB
Output Noise
,
A-weighted
< -68 dBu
Output Stage Topology Class H
Power Requirements 240 V, 230 V, 120 V or 100 V; 50 Hz to 60 Hz (factory configured)
L Series and C Series FIR-Drive Power
Amplifiers
Technical data | en 33
Bosch Sicherheitssysteme GmbH Installation manual 2017.10 | 02 | F.01U.327.801