EasyManua.ls Logo

Dynapac CA 252 - Maintenance Measures; Every 10 hours of operation (Daily)

Dynapac CA 252
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9CA 252/302/402 M252EN6
MAINTENANCE MEASURES
Item. in Measure See page Comments
fig. 1
Before starting each day
14 Check scraper setting 11, 12
1 Check for free circulation of cooling air 12
31 Check coolant level 12 See engine manual
2 Check diesel engine oil level 13 See engine manual
29 Top up fuel tank 13
6 Check fluid level in hydraulic reservoir 13
Check brakes 14
Every 10 hours of operation (Daily)
Item. in Measure See page Comments
fig. 1
4 Check that hoses and couplings are not leaking15
4 Inspect/clean the filter element in the air cleaner 15 Replace as required
17 Lubricate steering joint 16
18 Lubricate steering cylinders’ attachments 16
20 Check the wheel-nuts are tightened 17 New machine only
21 Check tire pressure 17
38 Inspect the air conditioning 17 Optional
Lubricate the strike-off blade bearings. 18 Optional
After the first 50 hours of operation change only the drum oil and all the oil filters.
Every 50 hours of operation (Weekly)
The periodic measures should be performed primarily
after the specified hours of operation. Use the daily,
weekly, etc. time periods only where this is not
possible.
Remove all dirt before filling, when checking
oils and fuel, and when lubricating with oil or
grease.
The engine manual specifies additional ser-
vice/maintenance instructions which relate to
the diesel engine.

Other manuals for Dynapac CA 252