Emergency procedures
2018-02-08 4812325555EN 31
Regeneration system
(Emission Control)
This equipment has a system of emission control and need
special care during the operation. This system has a particulate
filter (DPF) which accumulates pollutants throughout the
operation and must go through a regeneration process that
happens automatically, to eliminate the accumulated material.
When the machine is stationary with the engine running, if
necessary, the regeneration system will start.
! During regeneration, the engine increases its operation speed.
! Whenever regeneration is initiated, it is advisable to wait with
the equipment on and stopped to completion.
The equipment controls the level of contamination of the DPF in
5 stages: Empty, Low, Medium, High and Service.
When the accumulation in the DPF reaches the low level (Low)
contamination, the alert will be shown regeneration, indicating
that the machine will trigger automatic regeneration if the
machine is stopped.
When the accumulation in DPF reach the average level
(Medium) of contamination, the alert regeneration flashes and
yellow alert engine is activated. In this condition, it is
recommended to stop the machine at the first opportunity to
perform regeneration.
Fig. The level of accumulation in the DPF is
indicated on the display.
Fig. Low accumulation level
Fig. Medium accumulation level