Page #21 background imageLoading...
Page #21 background image
DI651ST2 User Manual 20
ITEM 1
ITEM 2
DEFAULT
DESCRIPTION
Information 2
Temperature
(BLU)
LCD inner (backlight unit) temperature monitoring.
Temperature
(Amb.)
LCD outer (ambience) temperature monitoring.
(temperature sensor installation is necessary)
ALS Level
(Amb.)
The brightness of ambience monitoring.
(Ambience Light Sensor)
ITEM 1
ITEM 2
DEFAULT
DESCRIPTION
Information 3
Over Heat
Protection
Inactive
It will enter into protection mode when the
display internal temperature is over heat.
56°C = Brightness 50%.
61°C = Brightness 25%.
66°C = Brightness 03%.
When the temperature is decreased to exit
the protection, the brightness will restore to
100% and Over Heat Protection is disabled.
Some functions may not be available for all models.
*Adjusted value: Each R/G/B value for this product has been individually adjusted during production to
a preset color temperature of 6500K.