EasyManua.ls Logo

dynasonics TFXL series - Page 18

dynasonics TFXL series
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
45°
45°
YES
YES
45°
45°
Z-Mount
Flow Meter
Mounting Orientation
DTTR, DTTN and DTTH Transducers
Top of
Pipe
YES
45°
45°
YES
45°
45°
Flow Meter
Mounting Orientation
2” DTTS and DTTC Transducers
Top of
Pipe
45°
45°
YES
YES
45°
45°
Flow Meter
Mounting Orientation
DTTS and DTTC Transducers
Top of
Pipe
45°
45°
YES
W and V Mount
Top of
Pipe
Figure 10: Transducer orientation for horizontal pipes
For DTTS and DTTC transducers, the transducers are V-mount. The frequency setting depends on the pipe material.
Pipe Size
Frequency
Setting
Transducer
Pipe
Mounting
Configuration
1/2 in. 2 MHz
DTTSnP ANSI
V
DTTSnC Copper
DTTSnT Stainless Steel
3/4 in. 2 MHz
DTTSnP ANSI
DTTSnC Copper
DTTSnT Stainless Steel
1 in. 2 MHz
DTTSnP ANSI
DTTSnC Copper
DTTSnT Stainless Steel
1-1/4 in. 2 MHz
DTTSnP ANSI
DTTSnC Copper
DTTSnT Stainless Steel
1-1/2 in. 2 MHz
DTTSnP ANSI
DTTSnC Copper
DTTSnT Stainless Steel
2 in.
1 MHz
DTTSnP ANSI
DTTSnC Copper
2 MHz DTTSnT Stainless Steel
DTTS transducer designation refers to both DTTS and DTTC transducer types.
Table 3: Transducer mounting modes for DTTS / DTTC
Transducer Installation
Page 18 April 2016TTM-UM-00369-EN-03

Table of Contents