Transducers
Transducer
Construction
DTTR NEMA 6*/IP67
PBT glass filled, Ultem, Nylon cord grip
PVC cable jacket; –40…250° F (–40…121° C)
DTTC NEMA 6*/IP67
CPVC, Ultem, Nylon cord grip
Polyethylene cable jacket; –40…185° F (–40…85° C)
DTTN I.S. NEMA 6P*/IP68
CPVC, Ultem, Nylon cord grip
Polyethylene cable jacket; –40…185° F (–40…85° C)
DTTH NEMA 6*/IP67
PTFE, Vespel, Nickel-plated brass cord grip
PFA cable jacket; –40…350° F (–40…176° C)
DTTS NEMA 6*/IP67
PVC, Ultem, Nylon cord grip
PVC cable jacket; –40…140° F (–40…60° C)
*NEMA 6 units: to a depth of 3 ft (1 m) for 30 days max. NEMA 6P units: to a depth of 100 ft (30 m) seawater equivalent
density indefinitely.
Cable Length 990 ft (300 meter) max. in 10 ft (3 m) increments; Submersible Conduit limited to 100 ft (30 m)
Pipe/Tubing Sizes 1/2 in. (12 mm) and larger
Pipe/Tubing Materials Carbon steel, stainless steel, copper and plastic
Software Utilities
ULTRALINK Used to configure, calibrate and troubleshoot flow meter. Compatible with Windows 2000, Windows XP, Windows Vista and Windows 7
Specications