4. Getting started
Dynaudio Acoustics BM14S 5
Controls and connections
1 AC IN
Mains power input.
2POWER ON (Main)
Main power switch (to switch the subwoofer manually on and off).
LED shows operation mode:
red: subwoofer switched on and in mute mode
green: subwoofer is activated
3 Power (Mode)
On: subwoofer is permanently on
Auto: subwoofer switches on when signal is detected
4Gain
Subwoofer volume level.
5 Lowpass
Subwoofer lowpass frequency: continuously variable from 50 to 150 Hz.
6 Phase
Phase setting: phase can be set to 0° or 180°.
7Mode
Subwoofer operation mode LFE or Slave:
LFE: setting for normal use and Master use
Slave: setting for second and all following subwoofers
8Highpass
Allows cutting off low frequencies of the signal provided at the
SAT/SUB
output:
Flat: signal is not processed
60: cut-off frequency at 60 Hz
80: cut-off frequency at 80 Hz
9 SAT/SUB (output)
Output for satellite system to be connected. This signal is processed according to
the Highpass setting.
10 SAT/SUB (input)
Input for full bandwidth signal. This signal will be processed according to the
Highpass setting and provided at the SAT/SUB output.
11 LFE
LFE/Slave: input for LFE signal
Slave: output to next subwoofer if installed
Terminal pinout (sockets 9, 10 and 11)
1 = 0 2 = + 3 = –
12
3
4
5
6
7
8
9
10
9
10
11

Questions and Answers: