A
WARNING:
For
room
sealed
fan assisted appliance,
the
boiler location
and
air/flue terminal position
must
obey
national
and
local requirements, gas safety
regulations
and
relevant standarts.
~
The
room sealed fan assisted boiler
is
not suitable for external installation.
It
should
be
within
in
the building.
-
In
case of gas leakage, it
is
necessary to vent the installation room according to national
and
local requirements, although the room sealed fan assisted boilers are independent
of
room
volume
and
ventilation.
A WARNING: Do
not
block
the
air vents which provide fresh air to
~
the
installation room.
~
The
air/flue terminal must
be
exposed to the external air
and
allow free passage of air cross
it
at
all times.
-
The
minumum
acceptable
dimensions from the terminal to obstructions
and
ventilation
openings must
obey
national
and
local requirements.
-
The
air/flue ducts should
be
fitted
at
a slight % 1 0 or 20 downwards incline to prevent
any
water or condensation from entering the boiler.
• Mounting The Boiler
Having determined the boiler location,
-
Use
the
paper
template to mark out the positions
of
the fixing holes of wall
and
mounting
brackets.
-
Drill
the wall
and
fix
the wall bracket to the wall with the 3 screws, then also the mounting
bracket with the 2 screws.
-Hang
the boiler
up
on the wall bracket.
E
E
~
fig.7