Product Notation
Table 1
Notation
Description
CA24
BB
Colora
24
kW
Open
Flued Gas
Combination
Boiler (bithermic type)
CA24
BM
Colora
24kW
Open
Flued
Gas
Combination
Boiler
(monothermic
type)
CA24
HB
Colora 24
IN/
Room
Sealed
Fan
Assisted
Gas Combination
Boiler
(bilhermic type)
CA24HM
Colora 24
IN/
Room Sealed
Fan
Assisted
Gas Combination
Boiler
(monothermic type)
CA28HM
Colora 28
IN/
Room Sealed
Fan
Assisted
Gas Combination
Boiler
(monothermic type)
Technical Data
Colora 24
kW
open
flued gas combination boiler (CA 24
BB)
is
a B type boiler
(EN
297). B type
boilers have
an
open
combustion chamber. Combustion air
is
provided from the installation
room
and
products of combustion
is
discharged
by
means of approved flue ducts connections
and
a chimney. Therefore, they are
named
as room air
dependent
gas appliances.
Colora
24/28
kW
room sealed fan assisted gas combination boilers (CA 24
HB,
CA 24
HM,
CA 28
HM)
is
a C type boiler
(EN
483). C type boilers have a sealed combustion chamber.
Required
fresh
air for combustion
is
provided independently from the installation room
by
concentric air/flue ducts
and
products
of
combustion
can
be
also discharged
by
the same
air/flue ducts. Therefore, they are
named
as
air independent gas appliances.
6
Table2
C4.24BB
C4.24BM
C4.24HB
C4.24HM
Gas
Category
*
112H31W
1121131¥'
112H31W
Boiler
Type
Bn
BS
c
1
2x.
c32x c
1
2x.
c32x
Type
of
gas
GaznakJel
Gazrduel
GaznakJel
Plcpcre Plcpcre Plcpcre
Alri»naJCES
Pmin, Min.
Heat
Output
8,4
8,4 8,4
Pmal<s,
Max.
Heat
Output
24
24
24
P%80,
Heat
Output
19,2 19,2
19,2
Qmin,
Min.
Thermal
Load
9,3 9,2 9,2
Qmal<s,
Max.
Thermal
Load
2M
26,2
26,2
Q%80,
Thermal
Load
21,3
21 21
GasConsurplion
Natural
Gas
(Max.
Load)
2,77 2,73
2,73
Natural
Gas
(Min.
Load)
0,97 0,96 0,96
LPG
2,08 2,08
2,08
Gas~~
Natural
Gas
2005
20'25 20'25
LPG
28137
28137 28137
lJotrleB:Hot.IM*r
Min.
Flow
Rate
For
Activating
3 3 3
Max.
Flow
Rate
1~t=34)
1Q:At=34) 1Q:At=34)
Min.
Operating
Pressure
0,3 0,3 0,3
Max.
Operating
Pressure
10 10 10
Set
Temperature
Range
35(:£)
35(:£)
35(:£)
CenlrallletiDJg
Min.
Operating
Pressure
0,8
0,8 0,8
Max.
Operating
Pressure
3 3 3
Set
Temperature
Range
4()..8() 4()..8() 4()..8()
General
Electrical
Supply
23CW
PC
-50
Hz
23CW
PC-
50
Hz
23CW
PC
-50
Hz
Electrical
Power
Consumption
105 150 150
Expansion
Vessel
8 8 8
Dimensions
(HxWxL)
7S0rA54lc340 7S0rA54lc340 7S0rA54lc340
Weight
(Net)
33,7 39,8
40,8
For
gas consumption
calculation;
Natural gas: Hu=9,59
kWh/m
3
LPG:
Hu=l2,793
kWh/kg
C4.28HM
Unit
112H31W
c12x.
C32x
Gazrduel
Plcpcre
9,8 kW
28
kW
22,4 kW
10,7
kW
30,6
kW
24,5 kW
3,19
m3Jh
1,12
m3/h
2,39
l<glh
20'25
mbar
28137
mbar
3
11/mln
12(At=33)
It/min
0,3
bar
10
bar
35(:£)
"C
0,8
bar
3
bar
4()..8()
"C
23CW
PC
-50
Hz
VAC/HZ
150
waH
8
It
7S0rA54lc340
mm
41,3
kg