E.C.A. CA 24 BB - Gas Type Conversion; Gas Pressure Adjustments

E.C.A. CA 24 BB
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
+
Ignoring
the
program
- If you want to turn off your unit while program
is
running or
if
you want to turn on the unit before
the program activates the device,
press
the
~
button.
Pressing
this
button while
device
is
running turns off the unit.
Pressing
this button before program activates the unit,
turns
on
the
device
immediately, unit stops running at the
end
of
program time.
This
button
works
only when
sliding button
is
at
RUN
position,
and
the
button sign appears on display.
+ Manual Control
--In
order to control the unit manually
use
sliding button
on
the left
of
the clock.
Unit
runs
continuously while sliding button
is
at
"I"
position.
Unit
stops running when sliding button
is
at
"0"
position.
Unit
runs
according
to program while sliding button
is
at
"AUTO"
position.
+ Resetting The Clock
-In
order
to
reset the clock,
press
R button while sliding button
is
at
"RUN"
position. All programs
set will
be
erased from the memory.
+ Programming
On
Winter Mode
-
Set
your program on the program timer.
-Set the turn
ON/OFF
button to ON.
-Set the temperature thermostat
to
any
level you
wish.
-Your unit
will
turn itself on when the timer reaches to time you have set
and
system will keep
the temperature constant
at
the level you set.
Unit
will turn
it
self off when
the
timer reaches
the time you
have
set
-
GAS
1YPE
CONVERSION
Gas
type conversion
from
LPG
to
natural
gas
or
from
natural
gas
to
LPG
must
be
carried
out
only
by
qualified
person.
-Gas
type conversion
can
be
divided
in 3 sections: gas pressure adjustments,
replacement
of the burner injectors
and
jumper adjusment.
Gas Pressure Adjustments
The
operating pressure varies depending on the type
of
gas. Therefore, minumum and maximum
operating
gas
pressure must
be
set
by
means
of
the adjusment screws that are
on
top
of
the
gas valve.
The
heat
output directly
depends
on
the operating pressure. When the operating
gas pressure
range
is
adjusted, minimum
and
maximum heat output
is
also adjusted
(mechanically).
32