28
Section 4 — Maintenance
Air-cooled Generators
4.12 SERVICE SCHEDULE
ATTENTION: It is recommended that all service work
be performed by the nearest Dealer.
SYSTEM/COMPONENT PROCEDURE FREQUENCY
X = Action
R
=
R
eplace as
N
ecessary
* =
N
otify
D
ealer if
R
epair is
N
eeded.
Inspect Ch ange Clean
W
=
W
eekly
M = Monthly
Y = Yearly
FUEL
Fuel lines and connections*
X M
LUBRICATION
O
il level
X M or 24 hours of
c ontinuous operation.
O
il
X 2Y or 200 hours
of operation.**
O
il filter
X 2Y or 200 hours
of operation.**
COOLING
Enclosure louvers
X X
W
BATTERY
R
e
m
ove corrosion, ensure
dryness
X X M
Clean and tighten battery
ter
m
inals
X X M
Check charge state
X
R
EVE
R
Y 6 M
Electrolyte level
X
R
EVE
R
Y 6 M
ENGINE AND MOUNTING
Air cleaner
X
R
2Y or 200 hours
S
park plug
(
s
)
X
R
2Y or 200 hours
GENERAL CONDITION
Vibration,
N
oise,
L
eakage, Te
m
perature*
X M
COMPLETE TUNE-UP* T
O
BE C
O
MP
L
ETE
D
BY A
D
EA
L
E
R
2Y or 200 hours
* Contact the nearest dealer for assistance if necessary.
** Change oil and filter after first eight (8) hours of operation and then every 200 hours thereafter, or 2 years, whichever occurs first. Change
sooner when operating under a heavy load or in a dusty or dirty environment or in high ambient temperatures.

Table of Contents