04/10 MN04020001Z-EN
Parameter menu (PAR)
87
PNU ID Access right
RUN
Value Description Factory setting
(P1.3)
P5.8 1457 / Current monitoring 0.00
0.00 – P7.2 A
Monitoring of the selected frequency range.
A monitoring message can be implemented via the digital outputs
(value 27 = P5.1, P5.2, P5.3).
P5.9 1458 / DO logic (control signal terminal 13) 0
Operation of transistor output DO-.
0 N/O contact.
1 N/C contact.
P5.10 1331 / RO1 logic (control signal terminals 22, 23). 0
Operation of relay contact R13/R14.
0 N/O contact.
1 N/C contact.
P5.11 1332 / RO2 logic (control signal terminal 24, 25, 26). 0
Operation of relay changeover contact.
0 N/O contact (R21-R24) or N/C contact (R21-R22).
1 N/C contact (R21-R24) or N/O contact (R21-R22).
P5.12 1459 / DO, on delay 0.00
0.00 - 320.00 s
P5.13 1460 / DO, off-delay 0.00
0.00 - 320.00 s
P5.14 1461 / RO1, switch-on delay 0.00
0.00 - 320.00 s
P5.15 1424 / RO1, off-delay 0.00
0.00 - 320.00 s
P5.16 1425 / RO2, switch-on delay 0.00
0.00 - 320.00 s
P5.17 1426 / RO2, off-delay 0.00
0.00 - 320.00 s