10. Specifications
Model PV238 PV240 PV250 PV260 PV270
Input (DC)
Nominal DC
Voltage
360V
Max. PV
Open Voltage
600V
Start-up Voltage 150V
Shutdown
Voltage
Typical 80V
Working Voltage
Range
100 ~ 515 V
Full Rating
Voltage Range
225 ~ 500V 200 ~ 500 V
MPPT Working
Range
105 ~ 500 V 105 ~ 500 V
MPPT Efficiency
> 99%
MPPT Tracker(s)
1
Max DC Current 19A 26A 32A 37A
Output (AC)
Nominal AC
Power @ 240Vac
/ 277Vac
3800W 4000W 5000W 6000W 7000W
Nominal AC
Power @ 208Vac
3800W
3800W 4600W 6000W 7000W
Max. AC Power @
240Vac / 277Vac
3800W
4000W 5000W 6000W 7000W
Max. AC Power @
208Vac
3800W
3800W 4600W 6000W 7000W
Nominal Voltage
Defaulted: 240 Split phase
Optional: 208V, 240V or 277V single phase (setting required)
Operational
Voltage Range
186V ~ 225V for 208Vac system
215V ~ 260V for 240Vac system
248V ~ 300V for 277Vac system
Nominal
Frequency
60Hz
Operational
Frequency Range
59.32Hz ~ 60.48Hz