EasyManua.ls Logo

EBS CPX200NB - Page 23

EBS CPX200NB
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CPX200NB ALARM CONTROL UNIT USER MANUAL 23 / 30
EN
Getting the name of partition
Command syntax
XXXX GETNAME=PARTITION,NR
Command description
Acquiring the name of the partition
XXXX user code
NR number of the partition, possibile values: 1 or 2
Example: 1234 GETNAME=PARTITION,1
Feedback message
GETNAME=PARTITION,NR,VALUE
or
GETNAME:ERROR
Feedback message
description
GETNAME=PARTITION,NR,VALUE partition name
GETNAME:ERROR command rejected by the system
Setting the phone number
Command syntax
XXXX SETTELNUM=ID,NUMBER
Command description
Setting the phone number for pointed index on the
phone number list
XXXX user code
ID index of phone number on the list, possible
values: 1 to 10
NUMBER phone number, on which the texts will be
send
Example: 1234 SETTELNUM=3,800123456
Feedback message
SETTELNUM:OK
or
SETTELNUM:ERROR
Feedback message
description
SETTELNUM:OK command accepted
SETTELNUM:ERROR command rejected by the
system

Other manuals for EBS CPX200NB