Maintenance Intervals
Units equipped with a Momentary STOP Switch automatically
return to RUN position. Engine can start unintentionally. Always
remove spark plug lead from spark plug before assembling or
performing maintenance procedures, otherwise serious
personal injury can result.
COMPONENT / SYSTEM MAINTENANCE PROCEDURE
REQ’D
SKILL
LEVEL
Daily or Before Use
Air Filter Inspect / Clean * 1
Automatic Oiler Inspect / Adjust 1
Oil Filter Inspect 1
Fuel System Inspect 1
Guide Bar & Sprocket Nose Inspect / Clean * 1
Saw Chain
Inspect / Sharpen / Replace / Ten-
sioning *
2
Sprocket Inspect / Replace * 2
Cooling System Inspect / Clean 2
Recoil Starter Rope Inspect / Clean * 1
Screws / Nuts / Bolts Inspect / Tighten / Replace * 1
Every Refuel
Fuel System Inspect 1
Guide Bar & Sprocket Nose Inspect 1
3 Months
Air Filter Replace * 1
Oil Filter Inspect / Replace * 1
Fuel Filter Inspect * 1
Fuel Cap Gasket Inspect * 1
Spark Plug Inspect / Clean / Replace * 1
Muffler Spark Arrestor Inspect / Clean / Replace * 2
Cylinder Exhaust Port Inspect / Clean / De-carbon 2