STORAGE PB-580H/T
42 X7505200705
© 12/2017 ECHO Inc.
STORAGE
During operation the muffler or catalytic muffler and
surrounding cover become hot. Always keep exhaust area clear
of flammable debris during transportation or when storing,
otherwise serious property damage or personal injury may
result.
Long Term Storage (Over 30 Days)
Do not store your unit for a prolonged period of time (30 days or longer)
without performing protective storage maintenance which includes the
following:
1. Store unit in a dry, dust free place, out of the reach of children.
Do not store in enclosure where fuel fumes may accumulate or
reach an open flame or spark.
2. Place the stop switch in the “OFF” position.
3. Remove accumulation of grease, oil, dirt and debris from exterior of
unit.
4. Perform all periodic lubrication and services that are required.
5. Tighten all the screws and nuts.
6. Drain fuel tank completely. Press purge bulb 6 -7 times to remove
remaining fuel from carburetor then drain the tank again. Close choke,
start and run the engine until it stops due to lack of fuel.
Engine
does not
crank
N/A
Internal engine
problem
See your dealer
Engine
runs,
blower
doesn't
work or is
weak/
uneven
Blower pipe
Pipe clogged
Build-up of
debris
Unclog
Pipe loose Vibration Tighten
Pipe damaged Wear/Misuse Replace
ENGINE PROBLEM TROUBLESHOOTING CHART
Problem Check Status Cause Remedy

Questions and Answers: