Fault Finding
Symptom Possible Cause Solution
Although a fresh battery has been fitted,
the Eclipse Ego will not switch on.
The battery has been fitted incorrectly.
Fit the battery correctly with the positive
terminal nearest to the side of the frame.
The battery terminals are not making
proper contact with the battery.
Remove the battery, gently bend the
terminals towards where the battery will
sit and then replace the battery.
The battery does not seem to last very
long.
The battery type is of a low quality. Use an alkaline or metal hydride battery.
Do not use a low quality or rechargeable
battery.
Eclipse Ego leaks from solenoid area. Check that 3 solenoid seals are intact
and seated correctly in their designated
pockets in the minifold.
Replace seals is damaged using Eclipse
Ego parts kits. Ensure seals are seated
correctly.
Damaged Eclipse Ego solenoid. Replace Eclipse Ego solenoid.
LPR is supercharging causing
intermittent leaking.
Clean LPR Piston seal.
Inspect regulator seal (in LPR piston)
and regulator seat (in LPR body).
Replace if necessary.
Check for damaged or incorrect seals on
Rammer.
Replace seals.
Is it leaking from the barbs? Check hose for cuts or replace barbs.