16
FAQ
Issue Type Cause Analysis Troubleshooting
Abnormal fan
It is not powered on or it is
not started;
There are foreign matters
at the air inlet or there are dirt
deposits on the fan blades;
The fan is not running.
Check the power supply or wiring, power
on correctly to start it;
Clean the air inlet lter, and regularly wipe
away the dirt on the fan blades;
Refer to the solution in [The fan is not
running].
Abnormal
cooling
The cooling function is not
turned on;
The ambient temperature
is up to the setting;
The ambient temperature
is too high/too low;
The air inlet/outlet is
obstructed;
The compressor is not
running;
Refrigerant leakage/
obstructed pipeline.
Check whether the mode and temperature
are set correctly;
Please refer to the range of operation
temperature when using it. It is normal if the
cooling performance decreases when it is
running at high ambient temperature since
the load is high;
Remove the obstruction to ensure that the
distance between the air inlet and the wall is
> 0.5 m;
Refer to the solution in [The compressor is
not running];
If the compressor functions normally, there
may be refrigerant leakage or obstructed
pipeline. Please contact the professional staff
for maintenance.
Abnormal
heating
The heating function is not
turned on;
The ambient temperature
is up to the setting;
The ambient temperature
is too high/too low;
The air inlet/outlet is
obstructed;
The compressor is not
running;
Refrigerant leakage/
obstructed pipeline.
Check whether the mode and temperature
are set correctly;
Please refer to the range of operation
temperature when using it. It is normal if the
heating performance decreases when the
ambient temperature is low;
Remove the obstruction to ensure that the
distance between the air inlet and the wall is
> 0.5 m;
Refer to the solution in [The compressor is
not running];
If the compressor functions normally, there
may be refrigerant leakage or obstructed
pipeline. Please contact the professional staff
for maintenance.
For problems not covered in the preceding table, please consult EcoFlow customer
service.

Other manuals for EcoFlow Wave 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EcoFlow Wave 2 and is the answer not in the manual?

EcoFlow Wave 2 Specifications

General IconGeneral
TypeMonobloc mobile air conditioner
Wi-FiYes
Noise level56 dB
Refrigerating mediumR290
Cooling capacity (max)5100 BTU/h
Heating capacity (max)6100 BTU/h
Air conditioner functionsCooling, Heating
Operating temperature (T-T)5 - 50 °C
Refrigerating medium weight130 g
Suitable for room area up to10 m²
Cooling capacity in watts (max)1500 W
Heating capacity in watts (max)1800 W
International Protection (IP) codeIPX4
Cooling capacity in watts (nominal)- W
Heating energy efficiency (COP, W/W)-
Connected load820 W
AC input voltage100 - 240 V
AC input frequency50/60 Hz
Power consumption (cooling)550 W
Power consumption (heating)600 W
Hourly energy consumption (cooling)- kWh
Product colorBlack, Grey
Weight and Dimensions IconWeight and Dimensions
Depth297 mm
Width518 mm
Height336 mm
Weight14500 g