5 Installation and assembly
Personnel:
n
T
rained person
n
Service personnel
Protective equipment:
n
Protective eyewear
n
Chemical-resistant protective gloves
WARNING!
In order not to contaminate the interior of the dispenser, we urgently advise
you to ensure the necessary sterility and cleanliness in all the steps listed
below either by wearing hygienically impeccable gloves (latex) or by
disinfecting your hands beforehand.
DANGER!
Risk of burns due to electrostatic charge
Ethanol burns with a hardly visible flame and can be ignited by static
electricity. It is therefore essential to ensure that your hands are dry after
using the disinfectant dispenser and before touching another person or
object in order to rule out static inflammation.
DANGER!
No mobile phones, heating systems, Dermados Station open lighting
systems etc. should be used within 0.5 m of them for explosion protection.
CAUTION!
Make sure that it is placed in a well-ventilated area (10 x / h) Dermados
Station so that the inevitable alcoholic vapours can escape.
When using one with canisters, Dermados Station the ventilation slots on
the canister cover must never be covered to prevent the risk of fire due to
outgassing.
Collect / wipe up possible leaks and spills of the canister with a suitable
agent. Do not use automatic systems such as hoovers, suction robots, etc.
for this purpose, as the solution containing alcohol can get caught in the
appliance and cause it to catch fire.
If a spill is detected in the dosing area or in the storage area, the machine
Dermados Station must be shut down until the leak is eliminated or
, if
necessary
, repaired.
Installation and assembly
21 MAN048961, Rev. 2-09.2020