SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
Skinman Soft Protect FF
116032E 5 / 12
aerosols)
178 mg/m3
Further information
AGS
Commission for dangerous substances
11
Sum of vapor and aerosols.
butanone
78-93-3
AGW
200 ppm
600 mg/m3
TRGS 900
Further information
DFG
Senate commission for the review of compounds at the work place dangerous
for the health (MAK-commission).
EU
European Union (The EU has established a limit value: deviations in value
and peak limit are possible)
H
Skin absorption
Y
When there is compliance with the OEL and biological tolerance values, there
is no risk of harming the unborn child
glycerin
56-81-5
AGW (Inhalable
fraction)
200 mg/m3
TRGS 900
Further information
DFG
Senate commission for the review of compounds at the work place dangerous
for the health (MAK-commission).
Y
When there is compliance with the OEL and biological tolerance values, there
is no risk of harming the unborn child
Biological occupational exposure limits
Substance name
CAS-No.
Control parameters
Sampling time
Basis
Alkyl ketone
Proprietary
Ingredient
2-butanone: 2 mg/l
(Urine)
Immediately after exposition
or after working hours
TRGS 903
8.2 Exposure controls
Appropriate engineering controls
Engineering measures
:
Effective exhaust ventilation system. Maintain air concentrations
below occupational exposure standards.
Individual protection measures
Hygiene measures
:
Handle in accordance with good industrial hygiene and safety
practice. Remove and wash contaminated clothing before re-use.
Wash face, hands and any exposed skin thoroughly after
handling.
Eye/face protection (EN 166)
:
No special protective equipment required.
Hand protection (EN 374)
:
No special protective equipment required.
Skin and body protection
(EN 14605)
:
No special protective equipment required.
Respiratory protection (EN
143, 14387)
:
None required if airborne concentrations are maintained below the
exposure limit listed in Exposure Limit Information. Use certified
respiratory protection equipment meeting EU
requirements(89/656/EEC, (EU) 2016/425), or equivalent, when
respiratory risks cannot be avoided or sufficiently limited by
technical means of collective protection or by measures, methods
or procedures of work organization.
Environmental exposure controls
General advice
:
Consider the provision of containment around storage vessels.
Section: 9. PHYSICAL AND CHEMICAL PROPERTIES