417101726_Ecoplus_PCB.docx
4 Programming Structures
4.1 Ecoplus V/P
4.2 Ecoplus – All Variants / Overview
SMALL
STANDARD
Issue: 2007-19
SEL
SEL
Programming Structure
Programming Structure
ECOPLUS V/P
ECOPLUS V/P
SERVICE
FUNCTIONS
PARAMETER
FUNCTIONS
CONFIGURATION
FUNCTIONS
EXIT
TIME/DATE
SETUP
DISPLAY
OK 99
ACCESS CODE
FUNCTIONS
BOOSTER SETPOINT
10.0 mS/cm
DET. DELAY TIME:
180 sec
TIME 12:00
DATE 04.08.97
SET WEEKDAY
MONDAY
FLUSHING?
NO
MESSAGE LANGUAGE
ENGLISH
ARE YOU SURE ?
NO
METERING
SOLID DETERGENT
DEVICE MODE
V VT VX
SEL
SEL
SEL
SEL
SEL
OK
12:00
ECOPLUS V(P)
ACCESS CODE
- - - -
Alternating
each 5 sec.
if access code
is wrong
SEL
SEL
RUNNING
PLEASE WAIT
SEL
NEXT
CALIBRATION
OK
SEL
SEL
ACTIVATE
TM CODE ?
DEACTIVATE
TM CODE ?
CHANGE
TM CODE ?
INPUT OLD CODE
0 0 0 0
INPUT NEW CODE
0 0 0 0
INPUT CODE
0 0 0 0
(if previously deactivated) (if previously activated)
SEL
SEL
SEL
SEL
SEL
CALIBRATIONFAULT
PUSH ANY BUTTON
SEL
NEXT
SEL
RESTORE
DEFAULT? NO
ARE YOU SURE ?
NO
This question
appears only, if there
was an activation of
restore default.
This question
appears only, if
there was a change
of the device type.
ENGLISH
FRANÇAIS
DEUTSCH
ITALIANO
NEDERLANDS
ESPAÑIOL
SOLID
POWDER
LIQUID
V VT VX
P PT PX
L LT LX
ARE YOU SURE ?
NO 0.0 mS 55C
DISHWASHER
TYPE: STANDARD
In TIMED-Mode
OVERSHOOT
PROTECTION: OFF
SUMMERTIME
AUTO ? ON
Software v2.00
If „YES“:
Time is 5 sec (fix)
Obligatory to set at
Ecoplus P!
OFF
10 … 100%
ZERO CALIBRATION
CONDUCT. SENSOR
CONCENTRATION
OFF mS/cm
DOSING TIME
OFF sec
In CONDUCT.-Mode
To proceed from one menu to the next press
NEXT
NEXT button.
Back to the starting level.
Press this button to proceed to a submenu,
or to scroll within a menu.
To increase a value within a menu.
To decrease a value within a menu.
Only visible if the corresponding function is activated.
SEL
( )
DET. DOS. MODE
CONDUCT.
CONDUCT.
TIME
SEL
▲OK
12:00
SERVICE
FUNCTIONS
PARAMETER
FUNCTIONS
CONFIGURATION
FUNCTIONS
EXIT
WASH:60C P1
OK
RINSE:80C 12:00
ECOPLUS xx
ACCESS CODE
- - - -
Alternating
each 5 sec.
if access code
is wrong
SEL
SEL
SELSEL
Issue: 2007-19
• print/display functions
• manual functions
• access code
• customer data
• product names
• calibration
• metering settings
• alarm settings
• time/date setup
• delete functions
• system adjustment
{
View depends
on type of unit
Programming Structure
Programming Structure
ECOPLUS (complete)
ECOPLUS (complete)
Software v2.00
To proceed from one menu to the next press
NEXT
NEXT button.
Back to the starting level.
Press this button to proceed to a submenu,
or to scroll within a menu.
To increase a value within a menu.
To decrease a value within a menu.
Only visible if the corresponding function is activated.
SEL
( )