EasyManua.ls Logo

Ecolab Elados EMP III-E00 - Electrical Data and Dimensions

Ecolab Elados EMP III-E00
202 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.4 Electrical data
Description
Pump
type
00160
Pump
type
00250
Pump
type
00540
Pump
type
00800
Pump
type
01200
Supply voltage
230 V/50/60 Hz ± 10%
(special voltages on request)
max. power consumption IN
115V 50/60 Hz 1,6 / 1,8 A
230V 50/60 Hz 0,8 / 0,9 A
3PE 400V 50/60 Hz 0,48 / 0,43 A
max. starting current IA
(» IN * 3,3)
115V 50/60 Hz 5,3 A / 5,9 A
230V 50/60 Hz 2,6 / 3,0 A
3PE 400V 50/60 Hz 1,6 / 1,4 A
Motor power
115V 50/60 Hz 0,09 kW
230V 50/60 Hz 0,09 kW
3PE 400V 50/60 Hz 0,09 kW
Fuse rating
115 V 4 A
230 V 2 A
Type of protection IP 55
Breaking capacity at circuit
with 24 V
Empty report output 24 V 3 A AC/DC
stroke signal output 24 V 0,3 A DC
Breaking capacity at circuit
with 230 V
Empty report output 230 V / 3 A AC/DC
Empty report output
stroke signal output
connection according to VDE is not permitted
10.5 Materials
Pump-head: PP, optionally PVDF, stainless steel 1.4571
Diaphragm: PTFE-EPDM composite
Seals: FPM (Viton B), optionally EPDM, Kalrez
Valve-balls: Keramik, wahlweise nichtrostender Stahl 1.4401, PTFE
Valve-springs: Ceramics, optionally stainless steel 1.4401, PTFE
Housing: Thermoplastic polyester
Colour: Blue, RAL 5007
Special versions available on request.
Technical data
56417102233 Rev. 3-03.2019

Table of Contents

Other manuals for Ecolab Elados EMP III-E00

Related product manuals