2 Safety
2.1
General Safety
DANGER!
If you assume that safe operation is no longer possible the pump must be put
out of service immediately and be secured against unauthorized use.
This is the case if:
is visibly damaged
appears no longer functional
prolonged storage under unfavorable circumstances has occurred
(carry out function check).
The following notes should be observed:
Before any work on the electrical section, disconnect power and secure
against being switched on again .
The safety provisions for handling chemicals must always be observed and,
if applicable, suitable protective clothing must be worn
Notes in the product data sheet of the used dosing medium has allways to
be observed.
The installation may only used with the specified supply and control voltage
in the technical data.
2.2 Intended Use
WARNING!
Proper use particularly includes the following points:
Only dose liquid, validated chemicals.
Depending on the material version, the dosing system is designed for acid
and alkaline products.
The temperature range, the permissible ambient temperature and the
maximum media temperature is permissible only as described in the
"Technical data".
The back pressure must not exceed 1 MPa (10 bar) according to DIN EN
809.
The operating voltage has to be produced only as described in the
"Technical data".
The pump was developed, designed and built for industrial and commercial
use. A private use is excluded!
Any use going beyond the intended use or any other use shall be
regarded as misuse.
Proper use also includes compliance with all operating instructions prescribed by the
manufacturer
, as well as with all maintenance and servicing conditions.
Safety