6.3.5.1 Setting the pulse multiplier or divisor
To menu operating mode will be set if incoming water flow pulses are multiplied or divided.
At pulse multiplication causes every incoming pulse in “n” (setting factor) metering stroke.
At pulse division will be of the incoming pulses in “n” (setting factor) cause 1 metering stroke.
6.3.6 Indicators in “External pulse processing” operation mode
Display in operation
Meaning
Pos
Description
Fig. 6.2
Pulse multiplication
(Example:
10 external pulses
become 20 strokes)
1
Pulse memory active
2
Number of pulses received
3
Set factor
Fig. 6.3
Pulse division
(Example:
10 external pulses
become 20 strokes)
6.3.6.1 Selecting
Press key function “MENU/EXIT”.
The main menu appears with the
“operation modemenu item
highlighted.
Press START/STOP key.
The operation mode menu which
appears is divided into: internal,
pulse and current.
Select the Internaloperation
mode using the Up or Down key.
Press START/STOP key.
Fig. 6.4
The “Internal operation modesubmenu appears and offers the following selection:
- Multiplication
- Division
Select the desired indicator using the Up or Down key.
Press START/STOP key.
The setting is applied immediately and the pump returns to the main menu.
Press the key function “MENU/EXIT
The display shows the current or recently set operation mode.
The new factor (n) can be selected in pulse operation setting mode.