By pressing the button P3 on the display the alarm can be reset. Try and repeat lighting after the
cooling phase.
FAN BROKEN ALARM
• Smoke extractor encoder is
not functioning or not correctly
connected
• Contact local Service Technician
• No electricity supply to smoke
extractor
• Contact local Service Technician
• The smoke extractor is blocked • Contact local Service Technician
DEPRESSION ALARM
• The combustion chamber is dirty
• Follow the cleaning operations of the stove as per the
instructions manual
• The ue is blocked • Check that the ue is clear and clean
• The vacuum switch is
malfunctioning
• Contact local Service Technician
THERMAL ALARM WITH
RESET
• The thermostat with manual reset
has intervened
• Reset the thermostat pressing the button on the back of the
stove (see Figure below this table)
• The centrifugal fan is defective • Contact local Service Technician
• Combustion in the re pot is not
optimal
• Switch off the stove, clean the re pot and regulate
combustion with the setting of the pellets
HOT SMOKE ALARM
• Combustion in the re pot is not
optimal
• Switch off the stove, clean the re pot and regulate
combustion with the setting of the pellets
• The centrifugal fan is defective • Contact local Service Technician
• IF THE PROBLEM CONTINUES, CONTACT YOUR LOCAL
SERVICE TECHNICIAN.
SMOKE SENSOR ALARM
• The smoke sensor is
malfunctioning
• Contact local Service Technician
• The smoke sensor has been
disconnected from the board
• Contact local Service Technician
AUGER BLOCKED
ALARM
• The auger does not load pellets • Contact local Service Technician
Unscrew the protection cap and press
the button to reset the thermostat alarm.