17
By pressing the button P3 on the display the alarm can be reset. Try and repeat lighting after the
cooling phase.
FAN BROKEN ALARM
Smoke extractor encoder is
not functioning or not correctly
connected
Contact local Service Technician
No electricity supply to smoke
extractor
Contact local Service Technician
The smoke extractor is blocked Contact local Service Technician
DEPRESSION ALARM
The combustion chamber is dirty
Follow the cleaning operations of the stove as per the
instructions manual
The ue is blocked Check that the ue is clear and clean
The vacuum switch is
malfunctioning
Contact local Service Technician
THERMAL ALARM WITH
RESET
The thermostat with manual reset
has intervened
Reset the thermostat pressing the button on the back of the
stove (see Figure below this table)
The centrifugal fan is defective Contact local Service Technician
Combustion in the re pot is not
optimal
Switch off the stove, clean the re pot and regulate
combustion with the setting of the pellets
HOT SMOKE ALARM
Combustion in the re pot is not
optimal
Switch off the stove, clean the re pot and regulate
combustion with the setting of the pellets
The centrifugal fan is defective Contact local Service Technician
IF THE PROBLEM CONTINUES, CONTACT YOUR LOCAL
SERVICE TECHNICIAN.
SMOKE SENSOR ALARM
The smoke sensor is
malfunctioning
Contact local Service Technician
The smoke sensor has been
disconnected from the board
Contact local Service Technician
AUGER BLOCKED
ALARM
The auger does not load pellets Contact local Service Technician
Unscrew the protection cap and press
the button to reset the thermostat alarm.