16
3.16 Description of Screen Displays
3.17 Description of Alarms
SCREEN DISPLAY DESCRIPTION
FINAL CLEANING The stove is switching off, the cooling phase is not yet completed
ON The ignition phase has started,the pellets are loaded into re pot
WAITING FOR FLAME The pellet’s are ignited by the hot air passing through the ignition candle
FLAME PRESENT The ame is visibile in the re pot
WORKING The stove has completed the switch ON phase; you can now change the power
MODULATION WORKING The set room temperature has been reached
T ON The room sensor is off or an external thermostat has been connected
COOLING/WAITING FOR START The stove is cooling DOWN. When stove has cooled down it will start automatically.
ON/WAITING FOR RESTART
The switch ON phase, when the stove is warm, started. The operation is same of
phase ON
HOT SMOKE
The max temperature of smokes is reached: to reduce temperature, feeding pellets
and air draft reduce at POWER 01
OFF The stove is off
IMPORTANT
IF DISPLAY SHOWS “HOT SMOKE“ THERE CAN BE PROBLEMS IN THE
COMBUSTION OF PELLETS. PLEASE CONTACT A SERVICE TECHNICIAN.
WARNING REASON SOLUTION
PELLETS FINISHED
ALARM
• The pellet hopper is empty
• Check whether there are pellets in the hopper and rell if
necessary.
• The raio-motor does not load
pellets.
• Empty the hopper to check that no foreign objects have fallen
inside which could prevent the correct functioning of the
auger.
• Pellets not loading. • Regulate the pellet setting.
• IF THE PROBLEM CONTINUES, CONTACT YOUR LOCAL
SERVICE TECHNICIAN.
BLACK - OUT
• No electricity supply during
working phase.
• Press the off button and repeat switching on the stove.
• IF THE PROBLEM CONTINUES, CONTACT YOUR LOCAL
SERVICE TECHNICIAN.
NO IGNITION ALARM
• The pellet hopper is empty
• Check whether there are pellets in the hopper and rell if
necessary.
• Setting of pellets and of intake
during ignition phase insufcient
• Contact local Service Technician
• The resistance for lighting is
defective or not in position
• Contact local Service Technician
LOW FLAME ALARM
• The pellet hopper is empty
• Check whether there are pellets in the hopper and rell if
necessary.
• Bad setting of pellet and air
during ignition
• Contact local Service Technician
FAN RPM ALARM
• The revolution of smoke fan
lowering more than 15% of speed
to fan congestion
• Contact local Service Technician