4.6 Access to the inspection hatches for cleaning the smoke
Remove the pellet heater and release the two screws that secure the hatches to the body of the pellet
heater. Clean the inside using a drum type vacuum cleaner.
4.7 Frequency of Component Cleaning
INSPECTION HATCH (2 ON
THE RIGHT SIDE)
INSPECTION HATCH
(1 ON THE LEFT SIDE)
GASKET
GASKET
GASKET
SCRAPER
Parts/Frequency 1 Day 2-3 Days 30 Days Yearly Performed By
Burn pot Owner
Burn pot grill Owner
Glass Owner
Flu Technician
Door gasket Technician
Heat Exchanger Owner
Combustion chamber Owner
Vacuum Hopper Owner
Clean T discharge Technician