© Edwards Limited 2010. All rights reserved. Page 3
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
D395-90-880 Issue E
2Technical data
2.1 Electrical data
2.2 Operating and storage data
2.3 Mechanical data
2.4 Display
Connector type CEE/IEC 320
Electrical supply 100 to 240 V a.c. 47 to 63 Hz
Power consumption 15 W maximum
Peak inrush current 20 A at 110 V a.c.
40 A at 240 V a.c.
Fuse The unit is protected by an internal fuse.
This fuse is not user replaceable.
Ambient operating temperature range 0
o
C to 40
o
C
Ambient storage temperature range -30
o
C to 70
o
C
Maximum ambient operating humidity Max 90% RH non condensing at 40
o
C
Maximum operating altitude 2000 m max
IP rating IP20. IP40 when panel mounted. For indoor use only.
Mass 0.33 kg
Dimensions (w x h x d) 96 x 48 x 165 mm
Panel cut-out 92
+0.8
x 45
+0.6
mm to DIN43700
Panel thickness 1.5 mm minimum
Type High brightness green LED 7-segment display
LED enunciators for units and display mode
Update rate 300 ms