Technical data
A352-03-880 Issue B
2.4 Electrical data: three-phase motors
For motor wiring information, refer to the wiring diagram supplied in the motor terminal box. Dual-voltage motors
can be configured to operate with either the high-range or low-range electrical supply.
Edwards supplies dual-voltage motors pre-set to the highest of the selectable voltages.
For motor current information, refer to the motor rating plate.
2.5 Lubrication data
Note: A Safety Data Sheet is available on request for the recommended oil.
Refer also to Section 3.5.2 and 3.5.3.
Nominal supply (V) Frequency (Hz) Power (kW)
ES65 200 50/60 1.5/1.8
380 60 1.8
380-400 50 1.5
230/460 60 1.8
ES100 200 50/60 2.3/3.0
380 60 3.0
380-400 50 2.3
230/460 60 3.0
ES200 200 50/60 4.5/5.6
380 60 5.6
380-400 50 4.5
230/460 60 5.6
ES300 200 50/60 6.0/7.5
380 60 7.5
380-400 50 6.0
230/460 60 7.5
ES630 200 50/60 12.5/15.0
380 60 15.0
380-400 50 12.5
230/460 60 15.0
Recommended oil Edwards Ultragrade 20
ES65 ES100 ES200 ES300 ES630
Oil operating level, after draining (litres) 445514

Table of Contents