A590-00-880
Issue D Original
Instruction Manual
iH Dry Pumping Systems
Description Item Number
iH80 A590-00-xxx
iH160 A590-10-xxx
iH160HTX A590-12-xxx
iH600 A590-20-xxx
iH1000 A590-30-xxx
iH1800 A590-40-xxx
iH1800HTX A590-42-xxx
iH1800NRV A590-50-xxx
iH1800NRV HTX A590-52-xxx
Where xxx is as follows:
460 V, 60 Hz, 3 phase 908
200/208 V, 50/60 Hz, 3 phase 945
380/415 V, 50 Hz, 3 phase 946
230 V, 60 Hz, 3 phase 957

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Edwards iH600 and is the answer not in the manual?

Edwards iH600 Specifications

General IconGeneral
Weight27 kg (60 lbs)
TypeDry pump
Flow Rate600 L/min
Maximum Pressure10 bar
Power Consumption1.1 kW
Ultimate pressure<6.7 x 10-3 mbar (<5 x 10-3 Torr)
Max Flow Rate600 L/min
Motor Power1.1 kW

Summary

Technical Data Overview

Electrical Data Specifications

Details electrical supply requirements, including voltage, frequency, and power consumption for various models.

Installation Guide

Connecting to Vacuum/Exhaust Systems

Steps for connecting the iH system to external vacuum and exhaust systems, with safety warnings.

Electrical Supply Connection

Instructions for connecting the iH system to the main electrical supply, including safety measures.

Emergency Stop Circuit Connection

How to integrate the iH system with an external emergency stop control circuit.

System Commissioning Steps

Steps to follow for initial system startup, checks, and verification after installation.

Installing Additional Safety Equipment

Recommendations for installing extra safety equipment, such as nitrogen flow measurement.

Operation and Control

System Start-up Procedure

Step-by-step guide for safely starting the iH pumping system.

Manual System Shut-down

Procedures for safely shutting down the iH system manually.

Automatic Shut-down Conditions

Details on how the iH system automatically shuts down in response to specific alarm conditions.

Unplanned Shutdowns and Alarms

Information on safety sensors, warnings, and alarms that trigger system shutdowns.

Emergency Stop Functionality

How to use the emergency stop switch to safely halt the iH system operation.

Maintenance and Safety Procedures

Safety and Maintenance Frequency

Guidelines for safe maintenance practices and determining the frequency of service.