6. Cleaning and maintenance
6.1 Disinfection and cleaning during
operation
Disinfect the machine during operation after every
cut with hot water (82° C).
6.2 Daily cleaning after completion
of the slaughter
Continuous reliable operation can only be assured if
the air dehider is kept hygienically clean at all times.
The machine should normally be disinfected before
each cleaning.
Observe the applicable safety and hygiene regula-
tions (DIN EN 1672)!
Disinfectants must not be allowed to come into di-
rect or indirect contact with foodstuffs. Rinse the
machine with clear water after disinfection.
6.2.1 Cleaning the air dehider
1. Disconnect the EFA 620 from the compressed
air network!
Disconnect the air dehider from
the compressed air network
before carrying out cleaning
work.
Clean the air dehider in hot water
with a cloth or sponge.
Disinfectants must not be
allowed to come into direct or
indirect contact with foodstuffs.
Do not use aggressive solvents!
Do not use steam or high-pres-
sure cleaners! Do not immerse
the machine in water!
2. Unscrew fixing bolt (9) with hexagon key (49).
3. Remove blade cover (8).
4. Remove dehider blade pair (5), clean in warm
water (Fig. 3 and 5) and oil on the inside with
acid-free, thin-bodied oil (001 365 612).
.
5. Wipe the housing (1) and blade cover (8) clean.
6. Before inserting the dehider blades (5), grease
the holding pins on the connecting arms (16)
and (17), bearing race (3), blade bushing (6) of
Do not immerse the opened
dehider hand piece in water!!
49