Check that all the devices have been successfully
house coded.
This can be done by counting the amount of blue
flashes on each RadioLINK base. The number of
flashes should correspond to the number of devices
in the system. e.g. if the system has 4 Alarms and a
remote controller (e.g. Ei450) the blue light on each
base will flash 5 times and repeat this pattern every
5 to 10 seconds.
To complete the commissioning, the system must
exit house code mode.
The units will automatically exit house code after
30 minutes. Once the house coding is completed
the system will not communicate with any other RF
devices.
The house code procedure can also be terminated
on demand. To do this, press the house code button
on one of the bases. When the blue light comes on
solid release the button. This unit will then send a
signal to all the other RF devices instructing them
to exit the house code mode.