3. Installation
Mains operated products should be installed by a qualified electrician
as per the requirements for Electrical Installations published as IEE
Wiring Regulations – BS7671 current edition.
Failure to install this unit correctly may expose the user to shock or fire
hazards.
This unit is not waterproof and must not be exposed to dripping or
splashing liquids.
Mixing the Live and Neutral connections will damage the alarm. Ensure
that the same colours are used throughout the premises for Live,
Neutral and Interconnect wires (if used).
WARNING
WARNING
WARNING
The Ei168RC must NOT be connected when the house wiring
insulation is being checked with high voltages. i.e. Do NOT use a high
voltage insulation tester on the Ei168RC.
WARNING
Alternative Energy Sources (Wind, Solar, UPS, etc.).
This product is designed to be connected to a Pure or True Sine Wave
230 Vac supply. If connecting to a power source that utilises an inverter,
e.g. PV solar panel or UPS, the Total Harmonic Distortion (THD) must
be less than 5%. If in doubt check with manufacturer of the inverter.
Light Dimmer Circuits
This product must not be powered from a light dimmer circuit.

Other manuals for Ei Electronics Ei168RC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ei Electronics Ei168RC and is the answer not in the manual?

Ei Electronics Ei168RC Specifications

General IconGeneral
BrandEi Electronics
ModelEi168RC
CategorySmoke Alarm
LanguageEnglish

Related product manuals