GB
- 20 -
11. Troubleshooting guide
Faults Cause Remedy
The equipment
does not start
- Power supply not connected - Check power supply
The equipment
does not pump
- Intake sieve clogged
- Discharge hose kinked
- Clean intake sieve with water jet
- Unkink the hose
The equipment
does not cut out
- Delivery side is leaking - Clean the delivery side
Insuffi cient pumping
rate
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Clean intake sieve
- Clean equipment and replace wear
parts
The equipment swit-
ches off after briefl y
running
- Motor circuit-breaker switches the
equipment off due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment off
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
Anl_GE_DW_1100_N_A_SPK9.indb 20Anl_GE_DW_1100_N_A_SPK9.indb 20 15.06.2018 09:53:0615.06.2018 09:53:06