EasyManua.ls Logo

EINHELL GE-PP 5555 RB-A - User Manual

EINHELL GE-PP 5555 RB-A
118 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GE-PP 5555 RB-A
Art.-Nr.: 41.704.25 I.-Nr.: 11019
9
D Originalbetriebsanleitung
Tauchdruckpumpe
GB Original operating instructions
Submersible pressure pump
F Instructions d’origine
Pompe refoulante submersible
I Istruzioni per l’uso originali
Pompa premente ad immersione
DK/ Original betjeningsvejledning
N Dyktrykpumpe
S Original-bruksanvisning
Dränkbar tryckpump
CZ Originální návod k obsluze
Ponorné tlakočerpadlo
SK Originálny návod na obsluhu
Ponorné tlakočerpadlo
NL Originele handleiding
Dompeldrukpomp
E Manual de instrucciones original
Bomba sumergible a presión
FIN Alkuperäiskäyttöohje
Uppopainepumppu
H Eredeti használati utasítás
Bemerülő nyomásszivattyú
Anl_GE-PP_5555_RB-A_SPK9.indb 1Anl_GE-PP_5555_RB-A_SPK9.indb 1 30.04.2020 13:33:0530.04.2020 13:33:05

Table of Contents

Questions and Answers

  • M
    Michael MorganAug 10, 2025
    Why EINHELL GE-PP 5555 RB-A Water Pump is not pumping?
    • M
      Michael GarrettAug 10, 2025
      If your EINHELL Water Pump isn't pumping water, it could be due to a couple of reasons. The intake sieve might be clogged, so try cleaning it with a water jet. Alternatively, the discharge hose might be kinked; make sure to unkink the hose.
  • D
    Dominique MaynardAug 19, 2025
    What to do if my EINHELL GE-PP 5555 RB-A switches off after briefly running?
    • M
      Mark RojasAug 20, 2025
      If your EINHELL Water Pump switches off shortly after starting, there are a couple of potential reasons. First, excessive water contamination may be triggering the motor circuit-breaker; in this case, unplug the power and clean the equipment and shaft. Second, the water temperature might be too high, also tripping the circuit-breaker. Make sure the water temperature doesn't exceed 35°C.
  • T
    Tina DavisAug 31, 2025
    Why is the pumping rate of my EINHELL GE-PP 5555 RB-A insufficient?
    • A
      Alexandra HawkinsAug 31, 2025
      An insufficient pumping rate in your EINHELL Water Pump can be caused by two main issues. The intake sieve may be clogged, requiring cleaning. Additionally, heavily contaminated or abrasive water impurities can reduce performance. In this case, clean the equipment and replace any worn parts.

EINHELL GE-PP 5555 RB-A Specifications

General IconGeneral
Power550 W
Max Flow Rate5500 l/h
Max Suction Depth8 m
Max Delivery Height50 m
Max Water Temperature35 °C
Power Cord1.5 m
Voltage230 V
Frequency50 Hz
Max Head50 m
Suction Connection1"
Pressure Connection1"
Hose Connection1"

Related product manuals