5-3. Imaging Problems (For Analog Only)
Problem Possible cause and remedy
1. Display position is incorrect. Use “Position” in the Setting menu to correct the image
position (see “Hor. Position”, Ver. Position” (page 22)).
If the problem persists, use the graphics board’s utility if
available to change the display position.
2. Vertical bars appear on the screen or a part
of the image is ickering.
Use “Clock” in the Setting menu to adjust it (see Clock
(page 22)).
3. Whole screen is ickering or blurring.
Use “Phase” in the Setting menu to adjust it (see “Phase”
(page 22)).
30
Chapter 5 Troubleshooting