6. TROUBLESHOOTING
Prior to servicing the equipment, reduce the pressure in the air tank to
zero and disconnect the equipment from the main power supply.
Only trained service personnel can perform the activities listed in the
troubleshooting guide.
Compressor does
not start
There is pressure in the air tank
In STANDBY mode, the compressor starts
when pressure decreases
Switched off main breaker in distribution system
Loose wire terminal – tighten
Power cord defective – replace
Interrupted winding of motor, damaged
thermal protection
Jammed piston or other part
Low compressor
performance
Leakage of air from pneumatic
distribution system
Inspect pneumatic distribution system – seal
loose connection
Large consumption of compressed air
Do not exceed max. flow (see Technical data)
Replace worn out piston rings
Replace the dirty air suction filter
Clean or replace the dirty suction filter
Low output
compressor
pressure
Leakage of air from pneumatic
distribution system
Inspect pneumatic distribution system – seal
loose connection
Large consumption of compressed air
Do not exceed max. flow (see Technical data)
Replace worn out piston rings
Replace the dirty air suction filter
Clean or replace the dirty suction filter
Replace the dirty elements
Motor has stopped
– thermal
protection of motor
off
Clean or replace the dirty blow down filter
Unit is hot, unventilated area
Compressor is
noisy (knocking,
metal noises)
Damaged piston bearing or bearing in
motor
Loose (cracked) belt of the air pump
hanger
Water coming out
of outlets
Dirty water trap in filter and filter
regulator
Clean or replace the water trap
Adjust using service software, replace
damaged unit