- 10 - - 11 -
USING TOP PORT AS INLET
Internal Tube
EK-Quantum
Kinetic TBE VTX
Fittings must be placed on the Top port before installing the
Internal tube! In other scenarios, you can damage the Top.
EK-Quantum Kinetic TBE 160 VTX combo unit:
The internal tube, which is enclosed in a mounting Kit,
can be used for fluid intake into the reservoir. Make sure
the sealing gasket on the internal tube is placed correctly.
EK-Quantum Kinetic TBE 120 VTX combo unit:
In the case of 120 Version, please follow these steps:
- Unscrew the reservoir and take off the pre-installed
Anticyclone
-
Remove the top part of the reservoir and attach the
internal tube on one of the three (3) G1/4 holes (make sure
that sealing gasket on the internal tube is placed correctly)
- Secure the top to the reservoir and make sure that all
gaskets are set appropriately.
CAUTION (120 version):
Using the internal tube and pre-installed Anticyclone at
the same time is strongly not recommended! This can
damage the Anticyclone!
EK-Fitting