9 MEASUREMENT - RECORDING YOUR READINGS (CG60DL ONLY)
The Model CG60DL is equipped with a data logging feature. This is a valuable reporting gauge for
inspection purposes. It increases efficiency by reducing the time it takes to manually record the
measurements during the inspection process. The gauge can then be connected to a computer or serial
printer to save and print the results of the inspection.
The gauge has a memory capacity of 1000 readings. Measurements are stored in up to 10 batches (files),
each consisting of up to 100 readings (memory locations).
9.1 SETTING-UP THE DATA LOGGER
1. Press ON/OFF key to switch on the gauge.
2. Press MEM key to activate the data logger.
The display will flash FILE F-01 (or the last batch used). There are 10 batches, numbered F-01 to F-
10.
3. Press the SEND key to enter batch setup. The current batch will be displayed (F-01, F-03, etc.)
4. Press the UP / DOWN arrow keys to scroll to the batch (1-10) that will be used.
5. Press the SEND key once again to select the batch.
The display will flash FILE F-04 (or the selected batch).
6. Press the MEM key, to access the memory locations in the batch selected.
The display will flash the current memory location (L007, L039, etc.), followed by the status of the
memory location. The memory location can contain one of three possible things:
a measurement that was previously stored
CG60_CG60DL_TMA_0498_00_01_23225_A6L.fm Page 28 Tuesday, November 22, 2011 12:19 PM