7-1
ELECTRICAL DATA
Revision Y05-01Service Manual - WMZ
7. ELECTRICAL DATA
7.1 Single Phase Units
MODEL WMZ 7 WMZ 12 WMZ 9
Power Supply
To indoor To indoor To indoor
1PH-230V-50Hz 1PH-230V-50Hz 1PH-230V-50Hz
Max Current, A 4.2 8.4 5.9
Circuit Breaker 10 15 10
Power Supply Wiring
No. X Cross Section mm
2
3x1.0 mm
2
3x1.5 mm
2
3x1.0 mm
2
Interconnecting Cable RCModel
No. X Cross Section mm
2
5x1.0 mm
2
+2x0.5 mm
2
(OCT senser)
5x1.5 mm
2
+2x0.5 mm
2
(OCT senser)
5x1.0 mm
2
+2x0.5 mm
2
(OCT senser)
Interconnecting Cable STModel
No. X Cross Section mm
2
4x1.0 mm
2
4x1.5 mm
2
4x1.0 mm
2
MODEL WMZ 17 WMZ 22
Power Supply
To indoor To indoor
1PH-230V-50Hz 1PH-230V-50Hz
Max Current, A 13 16
Circuit Breaker 15 20
Power Supply Wiring No.
X Cross Section mm
2
3x1.5 mm
2
3x2.5 mm
2
Interconnecting Cable RCModel
No. X Cross Section mm
2
5x1.5 mm
2
+2x0.5 mm
2
(OCT senser)
5x2.5 mm
2
+2x0.5 mm
2
(OCT senser)
Interconnecting Cable STModel
No. X Cross Section mm
2
4x1.5 mm
2
4x2.5 mm
2
NOTE
Power wiring cord should comply with local lows and electrical
regulations requirements.